Advertisement

Inspection Results and Output
13.4
Judgment Output
Note
If a trap has been specified for the programme, the trap is deleted
along with the programme.
Setting and Canceling NG Operation (Trap function/NG Display function)
Procedure:
1.
Set the register No. for the judgment condition that you want to set or cancel
(A: NG−Exec is displayed at the bottom left of the screen).
2.
When nothing is displayed to the left of the Register No., NG operation is not
set.
3.
Press A to display a T to the left of the Register No.
Press it again to display an N to the left of the Register No.
JD01=GE01
A button
A button
TJD01=GE01
A button
NJD01=GE01
4.
Press A again, and the N will disappear. This cancels the setting.
Example:
Judgement with Different Judgment Conditions
The table below shows examples of judgement with different
judgment conditions
OK OK
OK
NG OK
NG NG
Judgment result is ER if the judgment register could not be
referenced.
Order of priority of operators is as follows:
High
low
13 − 26
NG operation not set
T: Trap function set
N: NG display function set
+
Judgment
*
OK
OK OK
NG
OK
OK
OK
NG OK
NG
NG NG
(,)
/
*
#
+
Judgment
#
OK
OK OK
NG
NG
OK
NG
NG
NG OK
NG
NG NG
OCR Type A230
Judgment
/
Judgment
NG
OK
NG
OK
NG
OK
OK
NG

Advertisement