15.2
Executing a Group Move
6.
Press ENTER to complete the group move.
Notes
All results are cleared for checkers which have been group
moved.
Since the position the checkers are moved to becomes the
execution position for the next inspection, the amount of
adjustment may prevent a checker from being set within the
screen. (A situation where the setting position cannot be set
within the screen.) In this situation, an "Position is out of
image range." error message is displayed.
If this error occurs after a group move when several checkers
have been moved at once, the move is canceled for all
checkers and they return to their positions before the move.
When A is pressed to execute a group move, in some cases
an error message is displayed and the move does not occur.
− When the checkers being moved are adjusted by a position
− When the mask areas for the checkers being moved are
− When the checkers to be moved are adjusted by a position
− When no checkers exist for the specified position and
15 − 8
and rotation adjuster to that the X−coordinate is outside the
range 0 to 511, or the Y−coordinate is outside the range 0 to
479.
adjusted by a position and rotation adjuster to that the
X−coordinate is outside the range –511 to 1022, or the
Y−coordinate is outside the range –479 to 958.
and rotation adjuster, and that position and rotation
adjuster has generated an error.
rotation adjuster group.