Download Print this page

Panasonic A230 User Manual page 246

Machine vision system

Advertisement

Inspection Results and Output
13.4
Judgment Output
13.4 Judgment Output
13.4.1
About Judgment Output
The results of judgments performed on checkers and numerical calculation
programmes can be communicated to other devices.
The conditions for output are described here.
The image cannot be changed once you enter the Judgment menu, so if you wish to
be able to see a particular image during Judgment setup, change to the required image
before entering the Judgment menu.
(1)
TYPE[ 1] :
[9] JUDGMENT
Program
JD01=
JD02=
JD03=
JD04=
JD05=
JD06=
JD07=
JD08=
A:Start
B:−−−−−−−− C:Esc.
Time:
0.0ms
1.
Output register No.
Specify which output register the results of judgment are output from.
There are two different types of judgment output registers; internal judgment
registers (R) and registers for external output (D). You can set up to 32 registers
for the A220, and up to 8 registers for the A100. Only 8 registers can be shown on
screen at a time, but the screen can be scrolled with the cursor lever.
Note
The judgment results set in JR01 to JR32 (JR01 to JR08 for the
A100) are not externally output.
2.
Judgment
Displays the judgment result for the set judgment conditions (OK, NG, or ER).
3.
Judgment conditions programme
Displays the judgment conditions programme that has been set. The judgment
conditions programme can be up to 55 characters in length.
13 − 20
(3)
(2)
Jud.
−−
−−
−−
−−
−−
−−
−−
−−
OCR Type A230