Download Print this page

Panasonic A230 User Manual page 349

Machine vision system

Advertisement

OCR Type A230
Image capturing
− When a problem occurs in the process of capturing an image.
Example: When the camera settings and the connected camera do not match.
− When the image is not captured successfully.
Save data error
− When data is not saved properly, and writing original stored data to flash memory fails.
Parallel monitor within setting help
− When the ERR signal goes ON with the parallel monitor setting.
− When after an error is output before entering setting help, and you are taken out of
setting help and returned back to the main menu.
Errors will occur in spreadsheets when:
− A referenced checker does not exist.
− A formula is not registered in the referenced numerical calculation register or
judgment output register.
− A numerical calculation register or judgment output register that has generated an
error is referenced.
Errors will occur in the template re−registration process when:
− Smart Matching is not set. (a non−existent checker was specified)
− The specified checker number is set for an image from a camera other than that set
for the capture camera.
− The number of detected objects during re−registration at the execution position is 0.
− Execution of position adjustment for re−registration at the adjustment position
resulted in part of the template area protruding off the screen.
− You attempted to register an image without features.
− The quantity exceeds the limits.
Errors will occur in the numerical calculation register or judgment output register
when:
The numerical calculation register and judgment output register output up to the last
register number for which a formula is set (excluding numerical calculation output
control).
18.2
Error Signal Output Conditions (Parallel)
Error Output
18 − 5