Download Print this page

Panasonic A230 User Manual page 338

Machine vision system

Advertisement

Communications (Serial and Parallel)
16.11 Computer Link
− Communication settings
<ImageChecker communication settings>
[4] Environment
41. Communication mode
42. RS232C
421. Baudrate (bps)
422. Length
423. Stop Bit
424. Parity
43. Serial Output
432. Top Data Register
434. Output
435. Numerical calculation
436. Judgment
<PLC communication settings>
PLC system register settings (COM port)
No. 412 Communication mode
No. 413 Transmission format
Data length
Parity check
Stop bits
Stop code
Start code
No. 412 Communication speed setting
*Use the DIP switches to make the data length, parity, and stop bit settings for the
FP2 (CCU).
16 − 62
Computer link
9600
8
2
Odd
1
16
Out
Out
Computer link
8 bit
Odd
2
C
R
No STX
9600
OCR Type A230

Advertisement

loading