Setting Conditions For The Gs4000 Models - Hitachi GS4000 Series Installation Manual

Hide thumbs Also See for GS4000 Series:
Table of Contents

Advertisement

2.2 SETTING CONDITIONS FOR THE GS4000 MODELS

Table 2.2-1 below outlines the basic conditions required to install the GS4000 models. Users
should place the devices in the environment where all of the following conditions are satisfied.
When installing the device into a rack, the temperature inside the rack should be within the
range specified for the item "Temperature, operating" in Table 2.2-1 below.
Table 2.2-1
Item
Dimensions (W x D x H) in
mm
Weight (kg max)
Input voltage
Frequency
Input power required (KVA)
Heat generated (KW max)
Noise (Note 1)
Vibration
Dust (Note 2)
Temperature, operating
Temperature, non operating
Temperature, shipping or
storage
Humidity, operating
Humidity, non operating
Humidity, shipping or storage
Note 1: This should be checked 1 m away from the side panel of the unit.
Note 2: Based on the measurement of falling dust. (See the section 2.7 Environmental Conditions.
520-10-026-30X
Installation Requirements for GS4000 Models
GS4000 Model
80E1
160E1
440 x 490
440 x 490
x 230
x 441
45
80
Single phase
100 VAC (100 - 120V) /
200 VAC (200 - 240V)
50/60 (±1Hz)
1.2
2.4
1.1
2.2
55 db or less 60 dB or less 65 dB or less
2.45 m/s2 or less
5%/W or less(Note 2)
0~40℃(recommended value23~28℃)
-10~43℃
-25~60℃
10~85%(recommended value45~55%)
8~85%
5~85%(no condensation)
GS4000 Installation Guide Revision 4.00
320E (AC)
80E2
440 x 674
440 x 674 x 574
x 147
130
40
Single phase
-48 VDC (-40.5 - -57V) /
200 VAC
-60 VDC (-50 - -75V)
(200 - 240V)
N/A
4.0
1.0
3.8
1.0
55 dB or less 60 dB or less 65 dB or less
160E2
320E (DC)
440 x 674
440 x 674 x 574
x 289
70
120
2.0
3.8
2.0
3.8
2-3