GS4000 Installation Guide Revision 4.00
radius of long length: 100mm or more
1.
radius of short length: 50mm or more
2.
Also, the fabric of optic fiber cables should be tough enough to resist the mechanical stresses
caused by the folding, pulling, compressing or rubbing of cables frequently done at the time of
installation or the environmental stresses during installation.
(8)
Spray of Chemical Agents
Protect a device from a spray of pesticide or antiseptic by covering it when treating a room
where it is located.
(9)
Seismic Considerations
If the unit is to be installed where there is a chance of earthquakes, ensure that the device, as
well as any other cabinet or rack into which it is placed, is securely anchored. Failure to
consider the effects of a strong earthquake can result in damage to the unit and physical
injury to anyone nearby.
*
2-20
NOTE: The actual vibration inflicted upon a device during an earthquake can be
intensified by the architecture of the building and floor where the unit is located.
Generally it is said that the vibration felt on the fifth floor and up in a nine-story
building is intensified by two to three times what we would feel on the ground.
In a moderate to strong earthquake, this can cause racks to overturn and
unanchored equipment to bounce along the floor.