Hitachi GS4000 Series Installation Manual page 50

Hide thumbs Also See for GS4000 Series:
Table of Contents

Advertisement

GS4000 Installation Guide Revision 4.00
Table 1.1-14 LED Indications on the GS4000-320E (DC) Chassis
Name
FAN0
FAN1
FAN2
FAN3
BCU0
BCU1
PSU0 (NIF1/0)
PSU1 (NIF3/2)
PSU2 (NIF5/4)
PSU3 (NIF7/6)
PSU4 (NIF9/8)
PSU5 (NIF11/10)
PSU6 (NIF13/12)
PSU7 (NIF15/14)
NOTE 1: When a high port-density PSU-integrated NIF is installed, its action status is shown here.
NOTE 2: When a high port-density PSU-integrated NIF is installed, and even though the LED status is "Green(blinking)",
the NIF will not be active in the following cases:
During a time span of approximately 10 seconds after the LED status becomes "Green(ON)" after GS4000 is powered on.
The "close nif" command is entered from an operation terminal.
The "disable" configuration command is entered from an operation terminal.
NOTE 3: For a high port-density PSU-integrated NIF, the "OFF" status of LED means that exchanging the NIF is possible.
*
(5) Accessories
No accessories provided.
*
1-32
Color
Role
Shows the action status of FAN0.
Shows the action status of FAN1.
Green/Red
Shows the action status of FAN2.
Shows the action status of FAN3.
Shows the action status of BCU0.
Green/
Yellow/
Red
Shows the action status of BCU1.
Shows the action status of PSU0
(NOTE1)
Shows the action status of PSU1
(NOTE1)
Shows the action status of PSU2
(NOTE1)
Shows the action status of PSU3
Green/
(NOTE1)
Yellow/
Shows the action status of PSU4
Red
(NOTE1)
Shows the action status of PSU5
(NOTE1)
Shows the action status of PSU6
(NOTE1)
Shows the action status of PSU7
(NOTE1)
NOTE: Regarding the "close nif" command, see the manual " GS4000・GS3000 Software
manual, Operations Commands". As for the "disable" information, see the manual "
GS4000・GS3000 Software manual, Configuration Commands CLI -CLI Type 1
Hierarchical Input Format, Vol. 2".
NOTE: The rack mounting brackets of GS4000-320E (DC) are attached to its body
beforehand at the time of shipment.
NOTE: Do not install optional components from a GS4000 or GR4000 into devices other
than another GS4000 or GR4000. Doing this causes a fire or an electric shock.
Action Status
Green (ON): running in normal condition
Red (ON): failure detected
Green (ON): operation possible
Yellow (ON): locked out
Green (blinking): in preparation for startup
Red (ON): failure detected
OFF: BCU powered off (BCU
exchangeable)
Green (ON): operation possible(NOTE2)
Green (blinking): in preparation for startup
Yellow (ON): locked out
Red (ON): failure detected
OFF: PSU powered off
(PSU exchangeable(NOTE3))
520-10-026-30X