10.2

File Size Unit in Memory

The minimum unit of capacity for storing a file in the memory is referred to as the file size unit (cluster size).
File size unit based on memory area
CPU module
R08PCPU
R16PCPU
R32PCPU
R120PCPU
*1 The file size unit (cluster size) differs depending on the firmware version and production information of the CPU module. ( Page 747
Added and Enhanced Functions)
Data is written in the unit of the file size (cluster size). For example, when 464 bytes of CPU parameter is
written to the data memory on the R08PCPU, it is written as 2048 bytes of data because the file size unit of
the data memory is 2048 bytes.
File size unit of each SD memory card
SD memory card
NZ1MEM-2GBSD
NZ1MEM-4GBSD
NZ1MEM-8GBSD
NZ1MEM-16GBSD
File size unit
Program memory
128 bytes
Device/label memory
512 bytes
File size unit
32K bytes
10 MEMORY CONFIGURATION OF THE CPU MODULE
Data memory
2048 bytes
4096 bytes
8192 bytes
16384 bytes