Mitsubishi Electric MELSEC iQ-R Series User Manual page 662

Process cpu module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

No.
Name
SM1216
Data logging setting No.1
Data logging error
SM1217
Data logging setting No.1
Data logging data saving in
progress
SM1218
Data logging setting No.1
Logging data storage file
switching in progress
SM1220
Data logging setting No.2
to
SM1228
SM1230
Data logging setting No.3
to
SM1238
SM1240
Data logging setting No.4
to
SM1248
SM1250
Data logging setting No.5
to
SM1258
SM1260
Data logging setting No.6
to
SM1268
SM1270
Data logging setting No.7
to
SM1278
SM1280
Data logging setting No.8
to
SM1288
SM1290
Data logging setting No.9
to
SM1298
SM1300
Data logging setting No.10
to
SM1308
SM1312
Data logging setting No.1 to
to
10
SM1321
Data logging suspend/resume
flag
APPX
660
Appendix 4 List of Special Relay Areas
Data stored
Details
Off: No error
• This relay switches to on when a data logging function
On: Error
• This relay switches to off when the setting is registered or
Off: Not in progress
This relay turns on when data in the internal buffer is being
On: In progress
saved in the SD memory card with the data logging.
Off: Not in progress
This relay switches to on when storage file switching is in
On: In progress
progress.
Same configuration as the
Data configuration is the same as the setting No.1
setting No.1
(SM1210 to SM1218).
Same configuration as the
Data configuration is the same as the setting No.1
setting No.1
(SM1210 to SM1218).
Same configuration as the
Data configuration is the same as the setting No.1
setting No.1
(SM1210 to SM1218).
Same configuration as the
Data configuration is the same as the setting No.1
setting No.1
(SM1210 to SM1218).
Same configuration as the
Data configuration is the same as the setting No.1
setting No.1
(SM1210 to SM1218).
Same configuration as the
Data configuration is the same as the setting No.1
setting No.1
(SM1210 to SM1218).
Same configuration as the
Data configuration is the same as the setting No.1
setting No.1
(SM1210 to SM1218).
Same configuration as the
Data configuration is the same as the setting No.1
setting No.1
(SM1210 to SM1218).
Same configuration as the
Data configuration is the same as the setting No.1
setting No.1
(SM1210 to SM1218).
OffOn: Suspend
• When this relay changes from off to on, the data logging
OnOff: Resume
• When this relay changes from on to off, the data logging
error is generated.
by the stop command from CPU Module Logging
Configuration Tool.
function is suspended. In an off state of the data logging
start SM, no processing is performed.
function resumes. In an ON state of the data logging start
SM, no processing is performed.
Set by (setting
timing)
S (Status change)
S (Status change)
S (Status change)
Same
configuration as
the setting No.1
Same
configuration as
the setting No.1
Same
configuration as
the setting No.1
Same
configuration as
the setting No.1
Same
configuration as
the setting No.1
Same
configuration as
the setting No.1
Same
configuration as
the setting No.1
Same
configuration as
the setting No.1
Same
configuration as
the setting No.1
U

Advertisement

Table of Contents
loading

Table of Contents