Mitsubishi Electric MELSEC iQ-R Series User Manual page 563

Process cpu module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Error
Error name
Error details and cause
code
1BB0H
File name
• In redundant mode, the POFF(P)
specification
instruction (Changing the program
error
execution type to standby type (output
off)) has been executed for an SFC
program in which the program
execution type is set to scan
execution type.
• In redundant mode, the PSCAN(P)
instruction (Changing the program
execution type to scan execution
type) has been executed for an SFC
program in which the program
execution type is set to standby type.
1BC0H
Program
• In a redundant system with redundant
execution time
extension base unit, the program
error (redundant
execution time of the standby system
function)
exceeded 200ms. (The error is
detected in the standby system.)
1BD0H
System
• The systems were not switched.
switching error
There was a cause of system
switching failure. (The error is
detected in the control system.)
1BD1H
System
• The systems were not switched by
switching error
using the SP.CONTSW instruction
because SM1646 (System switching
by a user) was off. (The error is
detected in the control system.)
2000H
Module
• The module type set in the system
configuration
parameters ("I/O Assignment
error
Setting") differs from that of the
module actually mounted.
2001H
Module
• The I/O numbers set in the system
configuration
parameters ("I/O Assignment
error
Setting") are overlapping between
modules.
2002H
Module
• The number of points assigned to the
configuration
intelligent function module in the
error
system parameters ("I/O Assignment
Setting") is smaller than that of the
module actually mounted.
2004H
Module
• Nine or more CC-Link IE Controller
configuration
Network modules and/or
error
MELSECNET/H network modules are
mounted in the entire system. (The
CC-Link IE built-in Ethernet interface
module is included if the module is
used as a CC-Link IE Controller
Network module.)
• Five or more MELSECNET/H network
modules are mounted in the entire
system.
Stop/
Action
continue
Continue
• Check the detailed information
(error location information) of the
error by executing module
diagnostics using the engineering
tool, display the error program
(step) by clicking the [Error Jump]
button, and correct the program.
• Check the detailed information
(drive/file information) of the error
by executing module diagnostics
using the engineering tool, and
check the specified file.
Continue
• Set a program execution time of
the standby system to be within
200ms.
Continue
• Check the cause of system
switching failure in the detailed
information (system switching
information) of the error by
executing module diagnostics
using the engineering tool,
eliminate the error cause, and
switch the systems from the
engineering tool again. If the same
error code is displayed again, the
possible cause is a hardware
failure of the CPU module, base
unit, or tracking cable. Please
consult your local Mitsubishi
representative.
Continue
• To switch the systems by using the
SP.CONTSW instruction, turn on
SM1646 and then execute the
instruction.
Stop
• Re-set the module type in the
system parameters in accordance
with the CPU module or intelligent
function module actually mounted.
Stop
• Re-set the I/O numbers in the
system parameters in accordance
with the intelligent function module
or I/O module actually mounted.
Stop
• Re-set the number of points in the
system parameters in accordance
with the intelligent function module
actually mounted.
Stop
• Reduce the number of CC-Link IE
Controller Network modules and/
or MELSECNET/H network
modules to eight or less in the
entire system. (The CC-Link IE
built-in Ethernet interface module
is included if the module is used
as a CC-Link IE Controller
Network module.)
• Reduce the number of
MELSECNET/H network modules
to four or less in the entire system.
Detailed
Diagnostic
information
timing
Error location
At instruction
information,
execution
drive/file
information
Time
At END
information
instruction
execution
System
At system
switching
switching
information
execution
Error location
At instruction
information
execution
System
At power-on, at
configuration
RESET
information
System
At power-on, at
configuration
RESET
information
System
At power-on, at
configuration
RESET
information
System
At power-on, at
configuration
RESET
information
36 ERROR CODES
561
36.4 List of Error Codes
36

Advertisement

Table of Contents
loading

Table of Contents