Mitsubishi Electric MELSEC iQ-R Series User Manual page 640

Process cpu module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Event
Event
code
type
25000
Operation
25010
25200
26000
26001
2A200
2A201
2A202
2B000
2B001
2B002
2B003
2B004
*1 As for file-related events such as writing and deleting a file, the following files are targeted:
 Program file
 FB program file
 Parameter file
 Data logging setting file (common setting file, individual setting file)
*2 The engineering tool displays "Start-up information" in detailed information 1 only when the Process CPU with firmware version "06" or
later is used.
*3 Detailed information 2 is stored only when detailed information 1 is CPU module (3E00H).
37 EVENT LIST
638
37.2 Event List
Event
Detected event
category
Info
Online module
change
Online extension
cable change/
addition
System A/B setting
write
Redundant operation
mode change
(backup mode)
Redundant operation
mode change
(separate mode)
Warning
Memory
*1
initialization
Device/label zero
clear
*1
Folder/file deletion
System switching (by
a user)
Memory copy
execution by the
engineering tool
(control system)
Memory copy
execution by the
special relay and
special register
(control system)
Memory copy
execution by a user
(standby system)
Control system
forced start-up
Description
The online module change
processing completed.
Processing of the online extension
cable change/addition has
completed.
The system A/B setting was written
to the CPU modules.
The operation mode in a redundant
system was changed to backup
mode.
The operation mode in a redundant
system was changed to separate
mode.
The memory was initialized.
Values in a device or label were
cleared to zero.
A folder or file was deleted.
The systems were switched due to
the cause on the user side.
The memory copy function was
executed by the engineering tool.
The memory copy function was
executed by the special relay and
special register.
The memory copy function was
executed by a user.
One system was forcibly started as a
control system while waiting for a
start-up of the other system.
Detailed information
1
2
System
configuration
information
Extension cable
information
Operation
System A/B
source
setting
information
information
Operation
Drive/file
source
information
information
Device/label
information/
Device/label
clearing
information
Drive/file
information
System
switching
information
Operation
Control system
source
start-up cause
information
information