20.1.89 UPS (Uninterruptible Power Supply) Integration

20.1.89 UPS (Uninterruptible Power Supply) Integration
Description
An uninterruptible power supply unit (UPS) is a device that supplies power for several minutes to a
connected device when a power failure occurs.
Conditions
For details about UPS units that are compatible with the automatic shutdown feature of this PBX, consult
the seller where you purchased this PBX. If an incompatible UPS is connected and the UPS runs out of
power, the PBX will turn off without shutting down.
When power is restored after a power outage, the PBX operates in the following manner:
If the PBX did not shut down, normal operation continues uninterrupted.
If the PBX shut down and power remains in the UPS, the PBX must be started again manually. (The
power switch must be turned off and then on again.)
If the PBX shut down and no power remains in the UPS, the PBX starts automatically. (This is because
the PBX's power switch is on.)
Installation Manual References
4.10 Connection of Peripherals
PC Programming Manual References
4.1.1 Status—Equipment Status—UPS

20.1.90 Upgrading the Software

Description
The main software of the PBX, as well as the software of other connected devices can be updated either
manually or automatically.
Obtaining updates manually
Obtaining software updates (downloading the update to the PBX) can be done manually via Web
Maintenance Console. In this case, software updates can be obtained from an FTP server, a USB
memory device connected to the PBX, a NAS, or a PC that can access Web Maintenance Console.
Obtaining updates automatically
The PBX can automatically check for and download updates from an FTP server. Also, a notification e-
mail can be sent to specified e-mail addresses when an update becomes available and when it is
downloaded.
Also, the PBX can be configured to check for updates automatically, but not to download them.
Installing an update can be done either manually via Web Maintenance Console, or on a set schedule.
The software of the following types of devices and components can be updated:
Data Type
Main software data
Expansion Unit software data
LPR (software on a slot card) software
data
420
Feature Manual
Operating system data area on the PBX's mother board.
Operating system data area on an Expansion Unit's mother
board
Flash ROM on a slot card (e.g., DHLC4)
This includes the LPR software of Expansion Units.
Description
Document Version 2017-06