NEC Express5800/R120g Maintenance Manual page 138

Express server
Table of Contents

Advertisement

Chapter 2 Useful Features
8. When all settings are completed, select Accept, and then press the <Enter> key.
9. Press the <Esc> key, and select Yes for the confirmation message "Save Configuration?"
The configuration is saved.
10. Press the <Esc> key to return to the TOP menu screen.
11. On the TOP menu screen, select Objects, Virtual Drive, and then View/Update Parameters to check
the specified virtual drive information.
12. Press the <Esc> key to return to the TOP menu screen, and then select Initialize.
13. On the Virtual Drives screen, move the cursor to the virtual drive to be initialized, and then press the
<Space> key. The virtual drive is selected.
14. Press the <F10> key.
15. Select Yes to start initialization.
When the progress bar on the Init Of VD Is In Progress screen indicates 100%, initialization is
completed. Press the <Esc> key to return to the TOP menu screen.
16. For RAID1, check the consistency on the virtual drive that has been initialized.
See Chapter 2 (5.3.4 Check Consistency) for details.
17. Press the <Esc> key to return to the TOP menu and exit LSI Software RAID Configuration Utility.
138
Express5800/R120g-2E, T120g Maintenance Guide
5. RAID System Configuration

Advertisement

Table of Contents
loading