NEC Express5800/R120g Maintenance Manual page 208

Express server
Table of Contents

Advertisement

Chapter 3 Appendix
BMC Message on Lower LCD Line
Ambient Temperature Upper
Critical
CPU1-DIMM Area Temperature
Lower Non-Critical
CPU1-DIMM
Area
Upper Non-Critical
CPU1-DIMM Area Temperature
Lower Critical
CPU1-DIMM
Area
Upper Critical
CPU2-DIMM Area Temperature
Lower Non-Critical
CPU2-DIMM Area Temperature
Upper Non-Critical
CPU2-DIMM Area Temperature
Lower Critical
CPU2-DIMM Area Temperature
Upper Critical
Processor1 Thermal Control
Upper Non-Critical
Processor1 Thermal Control
Upper Critical
Processor2 Thermal Control
Upper Non-Critical
Processor2 Thermal Control
Upper Critical
DUMP Request !
Power Supply1 Failure detected A power supply unit abnormality
Power Supply2 Failure detected
Power Supply1 AC lost
Power Supply2 AC lost
Processor Missing
208
A temperature abnormality was
detected.
Temperature
Temperature
The dump button was pressed.
occurred.
No CPU is installed.
Express5800/R120g-2E, T120g Maintenance Guide
Cause
The cooling fan has failed or is clogged.
Contact your sales representative.
Wait until collecting the memory dump
data has finished.
Make sure that the power cord is
plugged in.
If this does not resolve the problem,
contact your sales representative.
Contact your sales representative.
1. POST Error Message
Solution

Advertisement