Chapter 3 Appendix
(1) Error messages
Error Message
8000
System variable is
corrupted.
8001
Real time clock error
Check date and time settings Incorrect date and time set on
8002
8003
System battery is dead -
Replace and run SETUP
8005
Previous boot incomplete -
Default configuration used
8006
System configuration data
cleared by Jumper.
8007
SETUP Menu Password cleared
by Jumper.
8020
BIOS update error.
8021
Recovery jumper is set, but
recovery images is not
found.
8800
DXE_NB_ERROR
8801
DXE_NO_CON_IN
8802
DXE_NO_CON_OUT
8803
PEI_DXE_CORE_NOT_FOUND
8804
PEI_DXEIPL_NOT_FOUND
8805
DXE_ARCH_PROTOCOL_NOT_AVA
ILABLE
8806
PEI_RESET_NOT_AVAILABLE
8807
DXE_RESET_NOT_AVAILABLE
8808
DXE_FLASH_UPDATE_FAILED
8830
PEI_RECOVERY_NO_CAPSULE
8831
PEI_RECOVERY_PPI_NOT_FOUN
D
8832
PEI_RECOVERY_FAILED
9000
Unsupported CPU detected
9001
Unsupported CPU detected on
CPU #1
9002
Unsupported CPU detected on
CPU #2
9021
Unsupported CPU Speed
detected on CPU #1
9022
Unsupported CPU Speed
detected on CPU #2
Cause
Illegal setup information of
BIOS was detected.
Real time clock error was
detected.
real time clock was detected.
The battery for storing system
settings is dead.
The previous POST processing
did not finish.
The setup utility settings were
cleared using the jumper.
The setup utility password was
cleared using the jumper.
BIOS update failed.
Recovery jumper is set, but
recovery of BIOS failed.
An error was detected during
initialization of chipset.
An error was detected during
initialization of console.
A flash ROM is corrupt.
The system was not reset
correctly.
The Flash ROM was not written
to correctly.
The Flash ROM was not
recovered correctly.
An unsupported CPU was
detected.
A CPU of which clock speed is
unsupported was detected.
Express5800/R120g-2E, T120g Maintenance Guide
Solution
Start BIOS Setup Utility (SETUP), and then
execute Load Setup Defaults and specify the
necessary settings.
If the same error is detected repeatedly in spite of
re-setting, contact your sales representative.
Start SETUP, and then specify the correct date
and time.
If the same error is detected repeatedly in spite of
re-setting, contact your sales representative.
Contact your sales representative.
After the replacement, start SETUP, and then
specify the correct settings.
Use SETUP to specify the correct settings.
Follow the steps described in Chapter 1 (7.
Resetting and Clearing the Server).
Start SETUP, and then setup each item again.
If the same error is detected repeatedly in spite of
re-setting, contact your sales representative.
This error message also appears when lithium
battery is removed.
Try BIOS update again.
If the same error is detected repeatedly, contact
your sales representative.
Contact your sales representative.
1. POST Error Message
197