NEC Express5800/R120g Maintenance Manual page 203

Express server
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
C114
BMC Fatal hardware error.
C115
Management controller
not responding
C116
Private I2C bus not
responding.
C117
BMC internal exception
C118
BMC A/D timeout error.
C119
SDR repository corrupt.
C11A
SEL corrupt.
C11B
BMC Mezzanine card is not
found.
C11C
BMC Mezzanine partition is
invalid.
BMC is in Forced Boot Mode. Detected that BMC is in Forced
C11D
Communication with BMC was
C11E
failed in previous boot
Backup Data of BMC Mezzanine
C11F
card has corrupted.
BMC Runtime FW corrupted.
C120
BMC Force Update FW corrupted. An error occurred on BMC
C121
BMC Configuration area
C122
corrupted.
BMC eMMC inaccessible.
C123
BMC eMMC mode error.
C125
BMC eMMC partition corrupted. An error occurred on BMC
C126
BMC eMMC format corrupted.
C127
BMC is in Update Mode.
C128
C300
Out-of-band setup
configuration failure
Cause
A hardware error was detected
in BMC.
Management controller does
not respond.
Private I2C bus does not
respond.
BMC internal error was
detected.
BMC A/D timeout error was
detected.
BMC error or illegal SDR data
was detected.
BMC error or illegal system
event log data was detected.
BMC Mezzanine card is not
installed.
A format error was detected in
BMC Mezzanine card.
Boot Mode.
Communication with BMC was
failed in previous boot
Inconsistency was found on
BMC mezzanine card.
An error occurred on BMC
Runtime FW.
Force Update FW.
An error occurred on BMC
Configuration area.
Failed to access to BMC
eMMC.
BMC eMMC mode error
eMMC partition.
A format error occurred on BMC
eMMC.
BMC is in update mode.
An error was detected while
accessing BMC Mezzanine
card.
Express5800/R120g-2E, T120g Maintenance Guide
Solution
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
Update the BMC firmware.
If the same error is detected repeatedly, contact
your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
Contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on motherboard.
If the same error is detected repeatedly, contact
your sales representative.
Unplug the power cord, wait for at least 30
seconds, and restart the server. If the same error
is detected repeatedly, contact your sales
representative.
Contact your sales representative.
Disconnect the power cord, wait for at least 30
seconds, and then restart the server. If the same
error is detected again, contact your sales
representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.