Off-Line Utility And Universal Raid Utility - NEC Express5800/R120g Maintenance Manual

Express server
Table of Contents

Advertisement

Chapter 2 Useful Features
5.8

Off-line Utility and Universal RAID Utility

The points to be noted when using Universal RAID Utility together with Off-line Utility are described below.
The name of Off-line Utility depends on Boot Mode. In Legacy Mode, Ctrl-R is used. In UEFI Mode, HII is used.
(1)
Terms
Some terms are different between Off-line Utility and Universal RAID Utility. When using Universal RAID Utility
together with Off-line Utility, replace the terms as shown in the table below:
Terms of Off-line Utility
Controller
Virtual Drive
Drive Group
Drive
(2)
Numbering
The numbers indicating RAID controller information differ between Off-line Utility and Universal RAID Utility as
shown in the table below.
See Universal RAID Utility Users Guide for details.
Controller (RAID Controller)
Virtual Drive (Logical Drive)
Drive group (Disk Array)
Drive (Physical Device)
RAID Controller
Logical Drive
Disk Array
Physical Device
Tips
raidcmd is a command provided by Universal RAID Utility. See Universal RAID Utility
User's Guide for details.
Item
Starts from 0
Starts from 0
Starts from 0
Starts from 0
Express5800/R120g-2E, T120g Maintenance Guide
Terms of Universal RAID Utility
RAID Viewer
RAID Controller
Logical Drive
Disk Array
Physical Device
Number
Off-line Utility
Universal RAID Utility
Starts from 1
Starts from 1
Starts from 1
To be assigned based on an
enclosure that contains the
physical device and its slot
number.
5. RAID System Configuration
raidcmd
179