 Outdoor unit installation in multi-row
NOTE: Following settings are not recommended in case of cooling by a low outside tempera-
ture.
Single parallel unit arrangement
CAUTION
• When the outdoor temperature is 0 °C or less, do not use the accessory drain pipe and drain
cap. If the drain pipe and drain cap are used, the drain water in the pipe may freeze in extremely
cold climate. (For reverse cycle model only.)
• In area with heavy snowfall, if the inlet and outlet of the outdoor unit is blocked with snow, it
might become difficult to get warm, and it is likely to cause product malfunction. Construct a
canopy and a pedestal, or place the unit on a high stand that is locally installed.
4-1. Space requirement
100 or
more
2,000 or more
600 or more
1,000 or more
- (03-13) -
Multiple parallel unit arrangement
Unit: mm
500 or
more
3,000 or more
600 or more
1,500 or more
4. Installation space