Sharp IV-S20 User Manual page 116

Compact image sensor camera
Table of Contents

Advertisement

Menu bar
Menu bar
The display of evaluation results can be cycled through in the order of the
MSR-CHNG
measurement numbers using the up and down keys.
(measure-
(Measurement 0 camera 1
ment change
Measurement 2
The display of the measurement results/numerical calculation results can be
REG-CHNG
(registration
cycled through in the order of the registration numbers in the measurement
change)
program using the up and down keys.
The PC monitor screen is displayed by pressing the SET key.
PC-MONTR
10-5 "PC monitor screen."
(PC monitor)
(X input, Y input, auxiliary relay, timer/counter, final numerical calculation result)
Press the SET key, and the screen will change to the next [SYSTEM SETUP]
SET-SCRN
menu.
(setting
· When the screen is returned from the [SYSTEM SETUP] menu to the MAIN
screen)
OPS MENU, if CAPTURE AN IMAGE has been set to "NO," the image will not
be cleared.
The object type number (00 to 15) can be changed using the up and dow keys.
· The object type number can be changed manually by setting the OBJ. NO.
MANL-TYP
-CHG
MANL MODE item to "YES." (See page 8·9)
· Every time the object type is changed, the image will be cleared. (However,
(manual
type change)
the image will not be cleared when CAPTURE AN IMAGE has been set to
"NO.")
The screen shows the measuring time determined by the following time
(from measurement start to measurement end).
(Only at changing type)
CCD exposure time
Type change
time
(Shutter speed)
Input I/F = Monitor display measurement time with parallel input
To decrease the measuring time:
1. Increase the shutter speed (page 9·117),
2. Change the CCD image capture mode (CAPTURE AN IMAGE) to PARTIAL-IMAGE
(see page 8·3), and
3. Set the result displays (MESSAGE DISPLAY and PATTERN DISPLAY) to "NO"
(see page 8·4 and 8·5).
Display the measured results for each mesurement program
· The IV-S20 can store the setting conditions*. "Measured result screen" and "Image brightness:
H/L" on the MAIN OPS MENU (operation screen) will be latched, even after reapplying the power.
* To store the data, select
[SYSTEM SETUP] menu.
[Image display area]
The size of the area (in pixels) where the image is displayed on the monitor is 512 (horizontal)
480 (vertical).
Origin (0, 0)
Description
Measurement 0 camera 2
Measurement 3)
Actual measured time
CCD image
capture time
processing time
Input I/F = Monitor display measurement time
with serial/CCD trigger
SAVE IN FLASH MEM, or
512
X axis
(Unit: pixels)
(511, 479)
7-3
Setting and Operating Outlines
Measurement 1
See section
Image
Measurement result
display time
OPERATIONS, on the
7

Advertisement

Table of Contents
loading