[NUMERIC CALC] (TYPE00-MEAS.1-INSPECT LEAD)
1CALC. RESULT N00(0~15)
2OBJECT TYPE NO MATCH[M] CORD[X Y] QTY[K]
3FORMULA
4UPPER&LOWER LIMIT +00000000.0~ +00000000.0
5OUTPUT
6RUN A TEST
7UPPER MENU
[MXD] 0MXD0
N00
+00000050.0~ 00000052.0
N01
N02
N03
Numerical calculation
1CALC.RESULT
(calculation result)
2OBJECT TYPE
3FORMULA
4UPPER&LOWER.LIMIT
5OUTPUT
6
TEST
(make a test run)
7UPPER MENU
· The number of formulas which can be set are dictated by the selections made in items 2 and 3 as follows.
Degree of match [M]/ Coordinates [X]/[Y]
Number of objects [K]/maximum distance
[MXD]/minimum distance [MND]
Maximum lead length [MXL]/minimum lead length [MNL]
Numerical calculation [NC]
Constant [C]
The numbers ranging from 0 to 3 in front of the characters are registration numbers. The numbers
ranging from 0 to 7 after the characters are numbers for the object to be measured.
· For more information on numerical calculations see section 9-2 [4] Numerical calculations.
Note: You must run a test using item 6
Return to the [TYPE00-MEAS1 to 3] and select item 9 OUTPUT CONDITIONS
Continued on the following page
MAX.DIST[MXD] MIN.DIST[MND]
MAX-L.LENG[MXL] MIN-L.LENG[MNL]
NUM-CALC[NC] CNST[C]
REG.0(0~3) MES-OBJ.0(0~7) N00(0~15)
+ - ∗
/
DEL. END
NO Y0(0~7) C000(0~107)
(SET KEY)
Set the recording and display the results from arithmetical operation for
specified output data at any value from 00 to 15.
Select the type of data being calculated.
A number of formula settings are used.
The first line will change according to the selection made in item 2.
Selection of 2
The degree of match with the
reference image [M] coordinates [XY]
Number of objects [K], maximum
distance [MXD], minimum distance
[MND], maximum lead length [MXL]
and minimum lead length [MNL]
Numerical calculations [NC]
Constant [C]
Note: Please use a smaller number for the number of formulas at N (00 to 15)
than that used for 1 CALC. RESULT N (00 to 15).
Set the upper and lower limits for decisions.
Set the output conditions for the results of calculations.
Pressing the SET key will record the settings details as well as run a test.
Returns you to the [TYPE00-MEAS1 to 3] menu.
2FORMULA
TEST before making any calculations.
9-79
Y0
00000051.0
OK
Setting details
The first line of the display
Record 0 (0 to 3) N0 (0 to 15)
Record 0 (0 to 3) Object to be
measured 0 (0 to 7) N0 (0 to 15)
ABS
(the second line will not be displayed)
+00000000.0 (the second line will not
be displayed)
Number of formulas
0M to 3M/0X to 3X/0Y to 3Y
0K0 to 3K7/0MXD0 to 3MXD7/
0MND0 to 3MND7
0MXL0~3MXL7/0MNL0~3MNL7
ABS/ /TAN/ATAN (00 to 15)
-99999999.9 to +99999999.9
Lead inspection
TAN ATAN N00 (0 to 15)