Sharp IV-S20 User Manual page 383

Compact image sensor camera
Table of Contents

Advertisement

Detalis about the improved functions in software version 2.02 (compared with version 2.01)
Item
Lead inspection
Increased number of leads the can be inspected (from 64 to 128 pins max.)
"Form 4" has been added to the control procedures, and a "QW" command
Computer link
has been added to the block write commands when the Mitsubishi is set.
Binary processing
VAR-RATE (variation rate) has been added to the THRSHLD-ADJ.
Communication
Blocks 60 to 77 have been added to the "Label measurement after binary
(general-purpose se-
conversion" operation.
rial) computer link
Changed data order for the block 0 of "Label measurement after binary conversion ".
Changed data order for the masurement programs
- Block 2 in distance and angle measurements, block 0 in lead
Computer link
inspection, block 0 in area measurement by binary conversion, block 0
in label measurement after binary conversion.
The reference image registration function, using input terminal X5, has
Parallel input X5
been extended to make it available with camera 2.
Binary image displays are set to "Yes" and the [MAIN OPS MENU] , the
measuring time is reduced.
[ Example of the measuring time ]
- Measurement conditions
Capture all images, registered window number = 1
Measurement window = Rectangle, upper left coordinates (0, 0),
Area measurement
by binary conversion
lower right coordinates (511, 239)
Mask window = Rectangle, upper left coordinates (0, 0),
Counting quantity
lower right coordinates (255, 119)
by binary conversion
- Measuring time
When the shutter speed is 1/60 sec., the measuring time is reduced
from 143 ms (version 2.01) to 101 ms (version 2.02).
When the shutter speed is 1/1000 sec., the measuring time is
reduced from 127 ms (version 2.01) to 85 ms (version 2.02).
Auxiliary relay C112
Changed functions of the auxiliary relays C112 (final evaluation result)
and C114 (CCD trigger status output).
Auxiliary relay C114
Change between
The menu display details in the English display mode have totally
the Japanese and
changed.
English display
modes
Newly added functions on software version 2.01 (compared with version 2.0)
Item
Latch the measurement results on the operation
Operation screen
screen after resetting the power.
When the measurement start input is general-purpose
Object type
serial input, the object type can be changed using the
change
type number specification instruction
(processing code 55).
Improved functions
Additional function
Appendix-4
Reference page
9-72
11-18, 14-24
9-51, 9-62
9-85, 9-93
9-101, 9-109
13-20, 14-12
13-19, 14-11
14-8 to 10
11-1
10-7
12-1
Reference page
Description of
paragraph 9 on
page 7-2 to 7-3
11-7 and 13-1.

Advertisement

Table of Contents
loading

Table of Contents