Lead inspection
Continued from the previous page
Select item 7 EVALUATION COND (evaluation conditions) on the [TYPE00-MEAS1 to 3] menu
[EVALUATION COND]
1REGST NO.
2X COORD
3Y COORD
4MATCH
5MEAS OBJ
6NUMBER
7DISTANCE
8L.LNGTH
9MAKE A TEST RUN (SET KEY)
0UPPER MENU
Items 2 to 4 and 6 to 8 will not be displayed if the setting at items 1 and 5 is REG.NO
(disable registration) on the [MEASURING COND] (mesurement condition) menu.
Evaluation conditions
1REGST NO.
(registration number)
2X COORD (X coordinates)
3Y COORD (Y coordinates)
4MATCH (degree of match
with the reference Image)
5MEAS OBJ
(measurement object)
6NUMBER (number of
9
objects)
7DISTANCE (distance
between edge centers)
8L.LNGTH (lead length)
9
0PRIOR MENU
· Check your selection by testing the upper and lower limits for the evaluations that you have set.
This can be done using item 9 MAKE A TEST RUN.
· For more information about evaluation conditions, see section 9-2 [3] Evaluation conditions.
[Measurement example]
Line used in
detecting the object
The brightness of the
part above the line used
to inspect the object.
Even if only one measurement of the distance between the center points of 2 adjacent leads (as
shown above) falls outside the range of the upper and lower limits specified, it will result in an NG
evaluation.
Return to the [TYPE00-MEAS1 to 3] menu and select item 8 NUMERIC CALC COND
(numerical calculation conditions).
Continued on the following page
(TYPE00-MEAS.1-INSPECT LEAD)
0(0~3)
[TEST RESULT]
000.0
511.0
000.0~479.0
-10000~ 10000
CRT.0-0(0~7)
000~128
000.0~702.0
000.0~702.0
Enter 0 to 3.
· Corresponds to the registration number entered in item 1 REGST NO.
(registration number) in the [MEASURING COND] menu.
Set the range that will produce an OK evaluation for the X and Y coordinates in
the reference image. These coordinates are set in the SEARCH CRITERIA
(reference search conditions) item on the [MEASURING COND] menu.
Set the range that will produce an OK evaluation for the degree of match with
the reference image.
Enter the measurement object number for the object being evaluated.
· Corresponds to the 3 OBJ NO. FOR MEAS (measurement object number) on
the [MEASURING COND] menu.
Set the number of objects (from 0 to 128) that can exist between the edge
detection points and still produce an OK evaluation.
Set the range of distances (from 0 to 702.0) between edge detection points that
will produce an OK evaluation.
· The longest and shortest distances will be displayed in the test results.
Set the range of lead lengths (from 0 to 702.0) that will produce an OK
evaluation.
· The longest and shortest distances will be displayed in the test results.
TEST RUN
Pressing the SET key will record the settings details as well as run a test.
This will return you to the [TYPE00-MEAS1 to 3] menu.
The distance (between the center of 2 adjacent leads)
[OUT]
000.0
OK
NO
000.0
OK
NO
+10000
OK
NO
003
OK
NO
050.0
OK
NO
048.0
100.0
OK
NO
097.0
Setting details
Lead length (all 5 leads)
The center point between edge detection points.
(Detection mode: center (dark))
Light
Dark
9-78
These displays can be set using
the up and down keys. (The
choices are NO, Y0 to 7, C000 to
C127)
Maximum distance
Minimum distance