Operation Examples (Degree of match inspection)
Continued from the preceding page
4. Move the cursor to the lower limit position with the left and right keys, and press the SET key.
- Select a digit with the left and right keys, and then set the value to +09000 with the up and
down keys. (Criteria for a successful match: 90.00% to 100.00%)
- After defining the lower limit, press the SET key and ESC key.
5. Move the cursor to 1 REGST NO. (register number) with the up and down keys, and press
the SET key. Enter the number "01" with the up and down keys, and press the SET key.
6. Move the criteria for a successful match (90.00% to 100.00%) for registration No.01, the
same as you did in steps 3 and 4.
3
7. Move the cursor to q UPPER MENU with the up and down keys, and press the SET key.
- The screen will return to the [TYPE00-MEAS1] (type: 00, measurement: 1) menu.
8. Press the ESC key.
- The screen will return to the [OBJECT TYPE COND] (conditions of object type) menu.
(10) Setting the final evaluation output condition
This setting is used to output the result of the final evaluation externally (see the following page).
- The final evaluation result is always output to the auxiliary relay C112. When the final
evaluation result is OK, C112 is ON, and when the result is NG, it is OFF. The result of final
evaluation can be externally output by using the auxiliary relay C112.
- The setting procedures are the same as described in item (9) in section 3-2 "Position
measurement."
PAGE0]
INPUT0
LOGIC
(11) Returning to the MAIN OPS MENU
1. Press the ESC key.
- The screen will return to the [SYSTEM SETUP] menu.
2. Press the ESC key.
- The screen will return to the MAIN OPS MENU.
Continued on the following page
2MATCH (MDL 0)
0
1
2
3
C112
- Move the cursor to 9 SAVE IN FLASH MEM (save data in flash memory) or 0
OPERATIONS with the up and down keys, and press the SET key.
- The following message will be displayed on the upper part of the screen.
DATA SAVE? (Do you want to save the data ?) (YES=[MOVE]/NO=[ESC])
- Press the SET key.
- The data saving operation will start, and the progress will be displayed on the bottom
of the screen.
REFERENCE IMAGE
SYSTEM I/O
MEAS CONDITIONS
When the data has been saved in the IV-S20 flash memory, the display will change from
"SAVING" to "SAVING COMPLETE"
Note:
· If the ESC key is pressed, the settings you entered will not be saved in the IV-S20
flash memory. In this case, if the power to the IV-S20 main husing is turned OFF, or
if the type No. is changed, the settings will be deleted.
- If the cursor was moved to 0 OPERATIONS in step 1, the screen will automatically
return to the MAIN OPS MENU.
+09000~+10000
4
5
6
7
OUT
Y00
SAVING
3-20