Return to the [MEASURING COND] menu and select item 5 OBJ CONDFOR MEAS
(conditions for objects to be measured)
Continued from page 9·74: Select OBJ CONDFOR MEAS (conditions for objects to be measured).
1DETECT MODE
2DETECT DIRECTION HORI(
3DETECT AREA
4THRESHOLD VALUE GRYS.050(0~255) EDGE.W (1~8)
5PROC. PROJECTION NO YES
6LEAD LNG MEAS DIR VERT Y=240
qUPPER MENU
· You can switch between displaying all of the headings together and displaying each one
separately using the ESC key.
1DETECT MODE
(detection mode)
2DETECT DIRECTION
(detection direction)
3DETECT AREA
(area of detection)
4THRESHOLD VALUE
(threshold values)
9
5PROC.PROJECTION
(artifact processing)
6LEAD LNG MEAS DIR
(direction of lead
length measurement)
qUPPER MENU
[Setting sequence of the conditions for objects to be measured of edge detection.]
1DETECT MODE
5PROC.PROJECTION
[Information about setting the conditions for objects to be measured]
In order to record a reference image it is necessary to freeze the frame.
· Specifications for the area of detection.
Line type
Dotted line
Continued on the following page
CNTR(BRT DRK)
MOVE UP.L(224,208) LO.R(287,271)
FLAT.W04(1~16)
Menu
Set the detection mode to BRT or DRK (center bright or center dark).
Select the detection direction.
Draw a dotted-line rectangle around the search area.
In order to enhance detection performance, make the Y dimension as
short as possible.
Set the width of the edge (1 to 8) and the flat (1 to 16), as well as the
difference in the light level (0 to 255).
Select whether to employ artifact processing or not.
-For more information about artifact processing see page 9·12
"Artifact processing", using shared settings.
When the measurement of lead length item is set to YES, set the
direction in which the measurement will take place.
This will return you to the [MEASURING COND] menu.
2DETECT DIRECTION
6LEAD LNG MEAS DIR
Movement
Size
Units of 1 pixel
Units of 1 pixel
) VERT(
)
Setting details
3DETECT AREA
)
Minimum
0 0 pixels
512 480 pixels
9-76
This is how the display looks when
YES is specified in item 4 LEAD
LENGTH MEAS (measurement of
lead length), on the [MEASURING
COND] menu.
If VERT (
) (vertical) is selected in
item 2 DETECT DIRECTION
(detection direction), then the
horizontal setting, HORI X=256, will
4THRESHOLD VALUE
qUPPER MENU
Maximum

Advertisement