Sharp IV-S20 User Manual page 152

Compact image sensor camera
Table of Contents

Advertisement

(1) The individual numerical calculations for each measuring program
The setting details and procedures for numerical calculations are the same for all measurement
programs with the exception of the point measurement program. In this section we explain the
use of the numerical calculations menu [NUMERIC CALC] for out of position measurements.
- The [NUMERIC CALC] (numerical calculations) menu for positional deviation measurement.
[NUMERIC CALC]
1CALC.RESULT
2OBJECT TYPE
3FORMULA
4UPPER&LOWER LIMIT +00000650.0~+00000700.0
5OUTPUT
6TEST A RUN
7UPPER MENU
* 2
00000002.0
N00
[C]
0X0 N 00
N01
[X]
* 1
00000400.0
N02
N03
Numerical calculation
1CALC. RESULT
(calculation results)
2OBJECT TYPE
3FORMULA
(registation number)
4UPPER&LOWER LIMIT
5OUTPUT
6TEST A RUN
(make a test run)
7UPPER MENU
· The number of styles may be set as follows, depending on the selections made in items
OBJECT TYPE
Coordinates X/Y
Coordinate deviation
Degree of match M
Angular deviation B
Numerical calculation NC
Constant C
(TYPE00-MEAS.0-POS-DEVIATION)
N00(0~15)
NO COORD[X Y] DEVIAT[x y] MATCH [M]
ANGL-DEV[B] NUM-CALC[NC] CNST[C]
REG.0(0~7) MDL0(0~1) N00(0~15)
DEL END
NO Y0(0~7) C000(0~107)
(SET KEY)
* 3
00000410.0
00000406.0
* 4
* 5
You may set the location where the arithmetical operation results of the specified output data
will be stored, from locations 00 to 15.
The results will be displayed 4 as one unit at position
Select the type of data being calculated.
A number of style settings are used.
· The style type is selected using the left and right keys and the numerical values are entered
using the up and down keys.
The settings are displayed at N00 to N15, position
The first line of the display will change, according to the selection made in item
Item
selections
Coordinates X and Y, positional deviation
coordinates x and y, degree of match M
Angular deviation B
Numerical calculation NC
Constant C
Note: Please enter a smaller number for N (00 to 15) in the formula than N (00 to 15) of item
1CALC. RESULT
Enter the upper and lower limits for making a judgment.
to N15, at position * 4 above.
Setting the output of the calculation results.
The output can be set to Y0 to Y7 or C000 to C107.
*
at position
6 above.
Pressing the SET key will store the setting details as well as run a test.
results of the tests and the OK or NG judgment will be displayed at position
Will return to the [TYPE00-MEAS0] menu.
Model 0
0X0 to 7X0 / 0Y0 to 7Y0
0x0 to 7x0 / 0y0 to 7y0
0M0 to 7M0
ABS /
/ TAN / ATAN (00 to 15)
-99999999.9 to +99999999.9
9-15
The display will be different for
each measurement program.
Ex.:
The coordinates [X] is multiplied
by 2 and the results is stored in
N01
1. The constant 2 is stored in
N00
2. The X1 value of the registra-
tion number and the value in
N00 are multiplied, and the
result is stored in N01.
Y0
OK
* 6
* 7
Setting details (selections)
*
1 above.
*
3 above.
The first line of the display
Record 0 (0 to 7) Model 0 (0 to 1) N00 (0 to 15)
Record 0 (0 to 7) N00 (0 to 15)
ABS
TAN ATAN N00(0 to 15) (second line is
not displayed)
+00000000.0 (second line is not displayed)
This setting will be displayed in N00
This setting is displayed in N00 to N15,
Model 1
0X1 to 7X1 / 0Y1 to 7Y1
0x1 to 7x1 / 0y1 to 7y1
0M1 to 7M1
0B to 7B
Shared settings
.
Both the numerical
*
*
5 and
7 above.
and
.
The numbers from 0 to 7 in
front of the characters are
registration numbers.
9

Advertisement

Table of Contents
loading

Table of Contents