Interface - Sharp IV-S20 User Manual

Compact image sensor camera
Table of Contents

Advertisement

Computer Link

14-4 Interface

The interface between the IV-S20 and a programmable controller from each manufacturer is described
below.
IV-S20
Settings for the IV-S20
[1] Setting items for the IV-S20
Communication speed
(k bit/sec)
Data length (bit)
Parity
Stop bit
Error check
Station No.
Write address
(up to 512 bytes)
14
See item [1] below.
Item
Setting details
115.2, 57.6, 38.4, 19.2, 9.6
7, 8
None, odd, even
1, 2
Checksum
Sharp: 00 to 37
Mitsubishi: 00 to 31
OMRON: 00 to 31
Sharp: 09000 to 99776
Mitsubishi: D000 to D9999
OMRON:DM0000 to DM9999
Programmable
controller
Sharp
[2]
Mitsubishi
[3]
OMRON
[4]
(8)