Sharp IV-S20 User Manual page 190

Compact image sensor camera
Table of Contents

Advertisement

Continued from page 9·50: When the GRAY-IMG-PROC (gray scale processing mode) is selected.
Continued from the previous page: When the binary processing mode is selected.
Select item 7 EVALUATION COND (evaluation conditions), from the [TYPE00-MEAS1 to 3] menu
[EVALUATION COND] (TYPE00-MEAS.1-DEG OF MATCH)
1REGST NO.
2MATCH (MDL0) -10000~+10000
3X COORD.(MDL0) 000.0~511.0
4Y COORD.(MDL0) 000.0~479.0
5LIGT LVL(MDL0) 000.0~255.0
6MATCH (MDL1)
7X COORD.(MDL1) 000.0~511.0
8Y COORD.(MDL1) 000.0~479.0
9LIGT LVL(MDL1) 000.0~255.0
eMAKE A TEST RUN (SET KEY)
rUPPER MENU
· You can switch between displaying all of the headings together and displaying each one
separately using the ESC key.
Evaluation condition
1REGST NO.(registration number)
2MATCH (MDL0) (degree of match with
the reference image)
3X COORD.(MDL0)
(X coordinates)
4Y COORD.(MDL0)
(Y coordinates)
5LIGT LVL (MDL0)
(light level)
6MATCH (MDL1) (degree of match with
the reference image)
7X COORD.(MDL1) (X coordinates)
8Y COORD.(MDL1) (Y coordinates)
9LIGT LVL (MDL1) (light level)
0MAKE A TEST RUN
qUPPER MENU
* The X and Y coordinates come from either the point of detection in the reference image.
· Check your selection by testing the upper and lower limits for the evaluations that you have
set. This can be done using item 0 MAKE A TEST RUN.
· For more information about evaluation conditions see (section 9·2 [3] Evaluaation condi-
tions).
Return to the [TYPE00-MEAS1 to 3] and select item 8 NUMERIC CALC COND
(conditions for numerical calculations)
Continued on the following page
0(0~15)
[TEST RESULT]
+09000
X=000.0
Y=000.0
116.0
-10000~+10000
09000
X=000.0
Y=000.0
100.0
Enter any number from 0 to 15.
Set the percentage of match with the reference image for model 0
that will still produce an OK decision.
Set the range of X(*) coordinates for model 0 that will produce an OK
decision.
Set the range of Y(*) coordinates for model 0 that will produce an OK
decision.
Set these items for model 1 just the same way as item 2 to 5
above.
Pressing the SET key will test the evaluation condition, display the test results.
This will return you to the [MEASURING COND] (measurement condition).
9·53
Degree of match inspection
[OUT]
These displays can be set
OK NO
using the up and down keys.
OK NO
(The choices are NO, Y0 to 7,
OK NO
C000 to C127)
OK NO
This is how the display looks
OK NO
when the GRAY-IMG-PROC
OK NO
(gray scale search mode) is
OK NO
selected and MODEL1 MEAS.
OK NO
OBJ (model 1 object to be
measured) is set to YES.
Setting details
9

Advertisement

Table of Contents