CO-to-CO Talk Mode Control
CO-to-CO Talk Mode Control
Software Version: CPC-S and CPC-M, Version 1 .O and
higher
Address:
FFl 2# l# 38# (0 or l)#
Description
Use this address to determine whether the DBS 824 system will use an
internal conference circuit for trunk-to-trunk conference calls, or whether it
will connect the trunks directly.
The CO-to-CO Talk mode is entered via the Call Forward-Outside feature or
the DISA Outgoing function. If an audio loop-back problem occurs when
trunks are connected directly, reset this program address to "Use a conference
circuit".
Programming
FFl 2# l# d## (0 or l)#
f
O=Connect the trunks directly (Default).
l=Use a conference circuit
Relited Programming
Automatic DISA Callers: FFl 2# 8# (l:lO)# (l?honeNo.)#
Unsupervised Conference Timer: FFl 3# 9# (O-15)#
Unsupervised Trunk Conference: FF2 (Trunk)# 16# (0 or l)#
.-.
. . .
Un%tperv&d Corrferencer~ FF%(Ext&rt)#: f3# -(O-or-l)#.
-^
.-
Notes
Limitation On Availabili~ Of Conference Circuits. The system can support
up to three conference circuits at a'tirne. If this programming address is set to
"1" (use a conference circuit), and a fourth CO-to-CO call is attempted while
three other conference calls are currently in progress, the system will connect
the trunks in the fourth call directly to each other.