Operator Access
FF7
Operator
Access
Software Version: CPC-S and CPC-M, Version 1 .O and higher
Address:
FF7 l# 17# (ExtPort)# (0 or l)#
Description
This Operator Access switch works only if the system is programmed to use
the new NANP dialing plan (FF7 l# 16## l#). Also, this switch applies only
to TRS types 2-6 (TRS types 0 and 1 do not allow outbound dialing; TRS
type 7 allows all dialing).
Use this address to block extension(s) from being able to access a trunk and
dialing "O", "OO", "1OxxXO" or "101xxxX0"
to reach an operator. This
would prevent a user from being able to circumvent a TRS restriction by
asking the operator to place a long-distance call.
If this switch is set to "Restrict" (default) and an extension user accesses a
trunk and dials the operator, the system will wait 6 seconds before
automatically disconnecting the call; if the user dials additional digits within
6 seconds, the system will check other switches (if programmed) to allow or
restrict the call, such as "International Calling On Extensions" (FF7 l# lS#),
"7-Digit Toll Restriction" (FF7 l# ll-15#), etc.
Programming
FF7 l# 17# (l-16
or
l-24)#
(0 or l)#
f
+
Extension Port
O=Restrict operator calls.
CPC-S: 1-16
l=Permit operator calls.
CPC-M: l-24
Related Programming
Dialing Plan Switch: FF7 l# 16# (0 or l)#
Equal Access Code Format: FF7 l# 20#/ (0 or l)#
7-l 2