Attendant Call Reversion Timer
FFl
Attendant
Call Reversion
Timer
Software Version: CPC-S and CPC-M, Version 1 .O and higher
Address:
FFl 3# 8## (O-12)#
Description
By default, the DBS 824 ultimately causes unanswered calls to revert to the
attendant.
For example, if an extension places a call on hold and the held call recalls to
the extension, the recall reverts to the attendant if it is not answered. Also, if
a transfer recall is not answered by the transferring extension, it also reverts to
the attendant
This timer determines how long an unanswered call will ring at the last
possible answering position before it reverts to the attendant.
For instance, if an extension parks a call, the parked call will recall if it is not
answered. The Attendant Call Reversion limer will determine how long the
park recall will ring at the extension before it reverts to the attendant. If the
Attendant Call Reversion Timer is set to default, the park recall will ring the
extension for 180 seconds before reverting to the attendant.
.
Programming
FFl 3# WI.
(0112)#
t
Reversion Timer @efault=9;
see the following table)
Table I-13. Attendiznt cd reversion timer values