Protection Zones
4

4.2 Activating/deactivating protection zones: CPROT, NPROT

840D
840D
NCU 571
NCU 572
NCU 573
4.2
Activating/deactivating protection zones: CPROT, NPROT
Programming
CPROT n,state,xMov,yMov,zMov)
NPROT (n,state,xMov,yMov,zMov)
Explanation of the commands and
parameters
CPROT
NPROT
n
state
xMov,yMov,zMov
Function
Activating, deactivating protection zones or
deactivate active protection zones for collision
monitoring.
The maximum number of protection zones which
can be active simultaneously on the same channel is
defined in machine data.
If no tool-oriented protection zone is active, the tool
path is checked against the workpiece-oriented
protection zones.
If no workpiece-oriented protection zone is active,
protection zone monitoring does not take place.
4-144
FM-NC
810D
840Di
Call channel-specific protection zone (for NCU 572/573 only)
Call machine-specific protection zone
Number of protection zone
Status parameter
0 = Deactivate protection zone
1 = Preactivate protection zone
2 = Activate protection zone
Move defined protection zone on the geometry axes