Preprocessing Stop Cancel Stopreof - Siemens sinumerik 840d Programming Manual

Hide thumbs Also See for sinumerik 840d:
Table of Contents

Advertisement

12.97
10
840 D
840D
NCU 571
NCU 572
NCU 573

10.4.3 Preprocessing stop cancel STOPREOF

Function
In the case of an explicitly programmed
preprocessing stop STOPRE or a preprocessing
stop implicitly activated by an active synchronized
action, STOPREOF cancels the preprocessing stop
after the next machining block as soon as the
condition is fulfilled.
Notes
STOPREOF must be programmed with the
vocabulary word WHEN and non modally (without ID
number).
Programming example
Fast program branch at the end of the block.
WHEN $AC_DTEB<5 DO STOPREOF
G01 X100
IF $A_INA[7]>500 GOTOF MARKER1=X100
 Siemens AG 2000. All rights reserved
SINUMERIK 840D/840Di/810D/FM-NC Programming Guide Advanced (PGA) – 04.00 Edition
10.4 Actions within synchronized actions
FM-NC
810D
840Di
CCU2
;Cancel the preprocess stop when distance to block end
is less than 5 mm.
;The preprocessing stop is cancelled after execution of
the linear interpolation.
;If the voltage 5 V is exceeded at input 7, jump to label 1.
Motion-Synchronous Action
10
10-361

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik fm-ncSinumerik 840diSinumerik 810d

Table of Contents