Siemens sinumerik 840d Programming Manual page 544

Hide thumbs Also See for sinumerik 840d:
Table of Contents

Advertisement

Tables
15
15.2 List of system variables
Identifier
Type
$AC_IW_TU
INT
INT
$A_PROBE
INT
$AC_MEA
$AC_TRAFO
INT
$AC_LIFTFAST
INT
15-544
Description: System variable/value range/index
$AC_IW_TU
Position information of the axes (MCS) for PTP travel
$A_PROBE[1]: Status of first probe
$A_PROBE[2]: Status of second probe
0 => not deflected
1 => deflected
n: Number of probe
$AC_MEA[n]
Probe has been triggered if TRUE (1)
n: Number of probe
1 – MAXNUM_PROBE
$AC_TRAFO
Code number of the active transformation according to machine data
$MC_TRAFO_TYPEn
$AC_LIFTFAST
Information about execution of liftfast.
0: Initial state.
1: Liftfast has been executed.
The variable is set to 1 by the NC at the start of the list fast process.
The program evaluating the variable (if one exists)
is set back to the basic setting ($AC_LIFTFAST=0) in order to be
able to detect a subsequent list fast.
SINUMERIK 840D/840Di/810D/FM-NC Programming Guide Advanced (PGA) – 04.00 Edition