15
Identifier
Type
$AC_ASUP
INT
 Siemens AG 2000. All rights reserved
SINUMERIK 840D/840Di/810D/FM-NC Programming Guide Advanced (PGA) – 04.00 Edition
Description: System variable/value range/index
$AC_ASUP
Code number for the cause of the ASUP activation. The reasons bit-
coded and have the following meanings:
BIT0: Activation due to: User interrupt "ASUP with Blsync"
Activation by: VDI signal, digital/analog interface
Continuation by: user-selectable Reorg or Ret
BIT1: Activation due to: User interrupt "ASUP"
For program continuation with Repos, the position after stopping is
stored.
Activation by: VDI signal, digital/analog interface
Continuation by: user-selectable
BIT2: Activation due to: User interrupt "ASUP from Ready channel
status"
Activation by: VDI signal, digital/analog interface
Continuation by: user-selectable
BIT3: Activation due to: User interrupt "ASUP in a manual mode and
Ready channel status"
Activation by: VDI signal, digital/analog interface
Continuation by: user-selectable
BIT4: Activation due to: User interrupt "ASUP"
For program continuation with Repos, the current position where the
interrupt occurred is stored.
Activation by: VDI signal, digital/analog interface
Continuation by: user-selectable
BIT5: Activation due to: Cancelation of subprogram repetition
Activation by: VDI signal
Continuation by: using system ASUP REPOS
BIT6: Activation due to: Activation of decoding single block
Activation by: VDI signal (+OPI)
Continuation by: using system ASUP REPOS
BIT7: Activation due to: Activation of delete distance to go
Activation by: VDI signal
Continuation by: using system ASUP Ret
BIT8: Activation due to: Activation of axis synchronization
Activation by: VDI signal
Continuation by: using system ASUP REPOS
BIT9: Activation due to:
Activation by: VDI signal
Continuation by: using system ASUP REPOS or RET (see MD.)
BIT10: Activation due to: Program continuation with teach-in or after
teach-in deactivation
Activation by: VDI signal
Continuation by: using system ASUP Ret
BIT11: Activation due to: Overstore selection
Activation by: PI selection
Continuation by: using system ASUP REPOS
BIT12: Activation due to: Alarm with reaction of compensation block
with Repos (COMPBLOCKWITHREORG)
Activation by: Internal
Continuation by: using system ASUP REPOS
BIT13: Activation due to: Retraction movement on G33 and Stop
15.2 List of system variables
Mode change
Tables
15
Part pro
Sync O S
RS
R
4
15-545