I/Os - Siemens sinumerik 840d Programming Manual

Hide thumbs Also See for sinumerik 840d:
Table of Contents

Advertisement

Tables
15
15.2 List of system variables
Identifier
Type
...
...
$AC_FIFO10
REAL
15.2.26

I/Os

$A_IN
BOOL
$A_OUT
BOOL
REAL
$A_INA
REAL
$A_OUTA
$A_INCO
BOOL
15-548
Description: System variable/value range/index
...
$AC_FIFO10[n]
FIFO for motion-synchronized actions and cyclic measurements
n: Parameter number 0 – max. FIFO element
Special meaning:
n=0: On write accesses with index 0, a new value is stored in the
FIFO,
On read accesses with 0, the oldest element is read and deleted from
the FIFO
n=1: Read access to oldest element
n=2: Read access to latest element
n=3: Total of all elements in the FIFO if bit 0 is set in MD
$MC_MM_MODE_FIFO
n=4: Read access to current number of FIFO elements
n=5–m: Read access to individual FIFO elements
5 is the oldest element
6 is the second-oldest, etc.
$A_IN[n]
Digital input NC
n: Number of input 1 – ...
The max. input number is determined by MD
$MN_FASTIO_DIG_NUM_INPUTS
$A_OUT[n]
Digital output NC
n: Number of output 1 – ...
The max. input number is determined by MD
$MN_FASTIO_DIG_NUM_OUTPUTS
$A_INA[n]
Analog input NC
n: Number of input 1 – ...
The max. input number is determined by MD
$MN_FASTIO_ANA_NUM_INPUTS
$A_OUTA[n]
Analog output NC
When writing, the value does not become active until the next IPO
cycle at which point it is read back.
n: Number of output 1 – ...
The max. input number is determined by MD
$MN_FASTIO_ANA_NUM_OUTPUTS
$A_INCO[n]
Comparator input
n: Number of output 1 – ...
The max. input number is determined by MD
SINUMERIK 840D/840Di/810D/FM-NC Programming Guide Advanced (PGA) – 04.00 Edition
04.00
15
Part pro
Sync O S
RS
W
R W +
4
RS
R
2
RS
W
R W
2
RS
R
2
RS
W
R W
2
RS
R
2
 Siemens AG 2000. All rights reserved