Mitsubishi Electric melsec q00ujcpu User Manual page 323

Programmable controller
Hide thumbs Also See for melsec q00ujcpu:
Table of Contents

Advertisement

(2) PLC system
Parameters required for use of the CPU module are set.
Parameter
Item
Low speed
Timer limit
setting
High speed
RUN
RUN-
PAUSE
PAUSE
contcts
Latch data backup
operation valid contact
Remote reset
Output mode at STOP to
RUN
Intelligent function module
setting (Interrupt pointer
100A
setting)
Module synchronization
100C
8 - 3
Figure 8.2 PLC system
Table8.2 PLC system setting list
Description
No.
Set the time limit for the low
1000
H
speed timer or high speed timer.
Set the contacts that control RUN/
PAUSE of the CPU module.
1001
H
Setting of only the PAUSE contact
is not allowed.
Set the valid contact device No.
1014
for backup of latch data to the
H
standard ROM.
Select whether to allow the
1002
H
remote reset from GX Developer.
Set the status of the outputs (Y)
1003
when the operating status is
H
switched from STOP to RUN.
Assign the interrupt pointers (I50
to I255) and set the start I/O
H
number and start SI number of
each intelligent function module.
Select whether to synchronize
CPU module startup with
H
intelligent function module
startup.
Setting range
1ms to 1000ms (in increments of 1ms)
0.01ms to 100.0ms (in increments of
0.01ms)
X0 to 1FFF
X, M, B
Selected/deselected
Previous state, Recalculate (output is 1
scan later)
• Start I/O No.
• Start SI No.
• I50 to 255
Selected/deselected
Default
Reference
100ms
Section 9.2.10
10.0ms
Section 9.2.10
Section 6.6.1
Blank
Section 6.6.2
Blank
Section 6.28
Deselected
Section 6.6.3
Previous state
Section 6.4
Blank
Section 9.11
Deselected
-
(To the next page)