Mitsubishi Electric melsec q00ujcpu User Manual page 485

Programmable controller
Hide thumbs Also See for melsec q00ujcpu:
Table of Contents

Advertisement

ACPU
Special
Special
Special
Relay after
Relay for
Relay
Conversion
Modification
M9103
SM1103
SM323
M9104
SM1104
SM324
M9108
SM1108
SM90
M9109
SM1109
SM91
M9110
SM1110
SM92
M9111
SM1111
SM93
M9112
SM1112
SM94
M9113
SM1113
SM95
M9114
SM1114
SM96
M9196
SM1196
SM325
M9197
SM1197
M9198
SM1198
M9199
SM1199
(10) QCPU with built-in Ethernet port
Number
Name
Time setting function
SM1270
(SNTP client)
execution
Remote password
SM1273
mismatch count clear
* 1: This applies to the Built-in Ethernet port QCPU.
12 - 19
Table12.11 Special relay
Name
OFF : Continuous transition
Presence/absence
of continuous
ON : Continuous transition
transition
Continuous
OFF : When transition is
transition
suspension flag
ON : When no transition
Step transition
monitoring timer
start (equivalent of
SD90)
Step transition
monitoring timer
start (equivalent of
SD91)
Step transition
monitoring timer
start (equivalent of
SD92)
Step transition
OFF : Monitoring timer reset
monitoring timer
ON : Monitoring timer reset
start (equivalent of
SD93)
Step transition
monitoring timer
start (equivalent of
SD94)
Step transition
monitoring timer
start (equivalent of
SD95)
Step transition
monitoring timer
start (equivalent of
SD96)
Operation output
OFF : Coil output OFF
at block stop
ON : Coil output ON
SM
1197
OFF
Switch between
blown fuse and I/O
ON
verify error display
OFF
ON
Data recovery of
OFF : Data recovery disabled
online sampling
ON : Data recovery enabled
trace/status latch
Table12.12 Special relay
Meaning
OFF : No time setting function
Set this to ON when executing the time setting function
(SNTP client) execution
(SNTP client).
ON : Time setting function
(Only when the time setting function is in "Use" with the
(SNTP client) execution
time setting parameter.)
To clear the acumulated numeber (SD979 to 999) of
OFF : Normal
mismatched remote passwords, the setting SM1273 is
ON : Clear
executed.
Meaning
• Set whether continuous transition will be performed for the
not effective
block where the "continuous transition bit" of the SFC
information device is not set.
effective
• OFF during operation in the continuous transition mode or
during continuous transition, and ON when continuous
completed
transition is not executed.
• Always ON during operation in the no continuous
transition mode.
• Turns ON when the measurement of the step transition
monitoring timer is started.
Turning this relay OFF resets the step transition
start
monitoring timer.
• Selects the operation output when block stop is executed.
ON
: Retains the ON/OFF status of the coil being used
by using operation output of the step being
executed at block stop.
OFF : All coil outputs are turned off. (Operation output
by the SET instruction is retained regardless of
the ON/OFF status of SM1196.)
I/O numbers
SM
to be
1198
displayed
OFF
X/Y0 to 7F0
Switches I/O numbers in the fuse blow module storage
X/Y800 to
registers (SD1100 to SD1107) and I/O module verify error
OFF
FF0
storage registers (SD1116 to SD1123) according to the
combination of ON/OFF of the SM1197 and SM1198.
X/Y1000 to
ON
17F0
X/Y1800 to
ON
1FF0
• Recovers the setting data stored in the CPU module at
restart when sampling trace/status latch is executed.
• SM1199 should be ON to execute again. (Unnecessary
when writing the data again from peripheral devices.)
Explanation
Corresponding
Details
Corres-
ponding
Set by
Corresponding
ACPU
(When Set)
M9
U
New
U
New
CPU
Qn(H)
QnPH
CPU
*1
QnU

Advertisement

Table of Contents
loading

Table of Contents