Step 5 The data configuration file is made and exported through the CME. This is usually performed
by configuration engineers.
Step 6 Store the files according to the following path, as shown in

Table 6-1 Saving path of the file

File
Upgrade software package
Configuration script
Data configuration file
----End

6.2.2 Arranging the USB Disk for Local NodeB Commissioning

The USB disk should be ready before it is used for local NodeB commissioning.
Procedure
Step 1 Prepare the USB disk with a LED. The requirements are as follows: when there is no read or
write operation on the USB disk, the LED on the USB disk is ON; when there is any read or
write operation on the USB disk, the LED on the USB disk is blinking.
Step 2 Check the compatibility of the USB disk with the NodeB. Do as follows to test the USB disk:
Insert the USB disk into the USB port on the WMPT of a NodeB that runs normally, and wait
for 3 seconds. If the LED on the USB disk blinked once, it indicates that the USB disk is
functional. If the USB disk fails the preceding test, change the USB disk.
Step 3 Save the related files in the USB disk according to the specified path.
1.
Issue 02 (2010-07-30)
ALL=GTMU|DRFU|GRFU
Where, ALL=XXXX is set by the user manually and it specifies the type of the board onto
which the software is to be loaded. In the preceding example, the software is to be loaded
onto the GTMU, DRFU, and GRFU.
CAUTION
All letters are in capitals, and different board names are separated by "|". Do not add
l
any comment or press the space or TAB key before or after "=" or the name of each
board.
The base stations using different configurations cannot use the same configuration file.
l
New configuration files should be created for the base stations of different
configurations.
Save the configuration script in ANSI characters.
Prepare the NodeB software package, data configuration file, and VSWR check script file.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 Commissioning the MBTS by Using USB and M2000
Table
Specified Path of the USB Storage
Device
\\BTS3900 GSM
\\BTS3900 GSM\Precfg.ini
\\BTS3900 GSM\SiteName\TranCfg.ini
6-1.
6-7