Viewing Service Verification Results - Huawei 3900 Series Commissioning Manual

Multi-mode base station
Hide thumbs Also See for 3900 Series:
Table of Contents

Advertisement

5 Commissioning the MBTS in GL or UL Mode on the
M2000
Procedure
Step 1 Choose Configuration > Auto Deployment > NodeB Auto Deployment to open the NodeB
Auto Deployment window.
Step 2 Right-click the commissioning task whose alarms are to be viewed, and then choose Open
Monitor Window from the shortcut menu.
In the displayed window, you can view the alarms of this NodeB and the relevant alarms of the
RNC managing this NodeB according to monitored objects. For details about the alarm
monitoring window, see
Step 3 Perform the following steps to diagnose the faults of boards, antennas, and E1T1s based on board
alarms, antenna alarms, and E1T1 alarms:
1.
2.
3.
4.
Step 4 Perform the following steps to handle an alarm:
1.
2.
3.
----End

5.6.3 Viewing Service Verification Results

After a NodeB commissioning task is at the service verification stage, the M2000 automatically
subscribes to the performance counters of the logical cells of this NodeB and checks whether
the NodeB services are normal based on the counter values. At this stage, you can check whether
each cell of the NodeB has passed the service verification and view the accumulated value of
each counter.
Context
l
l
5-30
5.13.1 Interface Description: NodeB
TIP
After you confirm the commissioning task, no alarm generated during the commissioning can be viewed
on the basis of a single NodeB on the Monitor tab page. If any uncleared alarm exists during the
commissioning, the alarm is reported again under Normal.
On the Monitor tab page, select a board, an antenna, or a physical transmission port, or
select an alarm of a certain object from the alarm list in the right pane.
Right-click the board, antenna, port, or alarm, and then choose Diagnose from the shortcut
menu.
Set the required diagnosis parameters.
After the diagnosis parameters are set, a diagnosis task is added to the diagnosis task list.
Right-click the fault diagnosis task, and then choose Diagnose Report from the shortcut
menu to view the diagnosis result.
Double-click the alarm to be handled.
In the displayed dialog box that shows the alarm details, click the link in Reason And
Advice.
Rectify the fault based on the alarm reference.
When the management status of a logical cell of the RNC to which the NodeB belongs is
Unblocked and the operation status is Enable, it indicates that the commissioning is at the
service verification stage. You can check whether a task is at the service verification stage
by referring to Description of the task.
At the service verification stage, the performance measurement period is the shortest
measurement period supported by the NodeB. There are certain rules for checking whether
NodeB services are normal. For details, see
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3900 Series Multi-Mode Base Station
Commissioning.
Service Verification
Rules.
Commissioning Guide