Performing A Nodeb Task Again Or Deleting The Task - Huawei 3900 Series Commissioning Manual

Multi-mode base station
Hide thumbs Also See for 3900 Series:
Table of Contents

Advertisement

3900 Series Multi-Mode Base Station
Commissioning Guide
l
l
Procedure
Step 1 Choose Configuration > Auto Deployment > NodeB Auto Deployment to open NodeB Auto
Deployment.
Step 2 Right-click the commissioning task whose alarms are to be viewed, and then choose Open
Service Verification Window from the shortcut menu.
In the displayed window, you can view the verification result of each cell and the accumulated
values of all the performance counters based on cells. For details about the service verification
window, see
----End
Service Verification Rules
l
l
l

5.6.4 Performing a NodeB Task Again or Deleting the Task

When a NodeB commissioning task is running, you can perform this task again or delete this
task.
Prerequisite
The NodeB deployment list is imported successfully.
Context
When the NodeB version software is being downloaded, the restart is performed after the FTP
service is complete. Therefore, you need to wait for a certain period to view the operation result
on the M2000.
Procedure
Step 1 Choose Configuration > Auto Deployment > NodeB Auto Deployment to open NodeB Auto
Deployment.
Step 2 In the commissioning task list, select the commissioning task to be performed again or deleted.
You can select multiple commissioning tasks.
Step 3 Right-click a commissioning task, and then choose the required menu item from the shortcut
menu.
Issue 02 (2010-07-30)
If a NodeB passes the service verification, the status of its commissioning task
automatically changes to Waiting for Acknowledgement. In such a case, you need to
manually confirm that the commissioning is complete.
The M2000 automatically clears the service verification measurement data that is generated
two weeks ago. This avoids a large amount of unnecessary history data on the M2000 server.
5.13.1 Interface Description: NodeB
If the value of a single performance counter is not 0 during the service verification, it
indicates that this counter has passed the verification.
If all the performance counters of a cell have passed the verification, it indicates that this
cell has passed the verification.
If all the logical cells of a NodeB have passed the verification, it indicates that this NodeB
has passed the verification.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Commissioning the MBTS in GL or UL Mode on the
Commissioning.
M2000
5-31