4 Commissioning the MBTS in GU Mode on the M2000

4.6.2 Handling MBTS Alarms

This section describes how to handle MBTS alarms. After the automatic software commissioning
starts, you can use the M2000 to monitor the alarms of an MBTS and the relevant alarms of the
controller that manages the MBTS in real time. If exceptions occur during the commissioning,
you can view the alarm information to locate and handle faults in time.
Prerequisite
The automatic software commissioning already starts, and you have not confirmed the
completion of the commissioning yet.
Context
M2000displays all the alarms reported during the MBTS commissioning based on object types.
l
l
Procedure
Step 1 Choose Configuration > Auto Deployment > MBTS Auto Deployment. The MBTS Auto
Deployment window is displayed.
Step 2 From MBTS List, select an MBTS whose alarms you need to view, and then click
toolbar. The alarm monitoring window is displayed.
For details about the alarm monitoring window, see
Commissioning.
Step 3 Select the object to be viewed in the left pane of the alarm monitoring window, and then view
the alarm information about this object in the corresponding area in the right pane.
Step 4 Handle MBTS alarms.
1.
2.
----End
4-18
The alarms of GBTSs are categorized as the following types: E1T1 alarms, IP alarms,
software alarms, board alarms, antenna alarms, cell service alarms, and other alarms. Other
alarms refer to the alarms that cannot be categorized on the basis of specific objects.
The alarms of NodeBs are categorized as the following types: E1T1 alarms, IP alarms,
antenna alarms, board alarms, cell alarms, external alarms, and other alarms. Other alarms
refer to the alarms that cannot be categorized on the basis of specific objects.
NOTE
If you select an MBTS to view its alarms, you can view the alarms of both the GBTS and the NodeB.
l
If one base station is normal and only the other base station is deployed, the deployed base station
provides the entries of alarm classification and fault diagnosis, whereas the normal base station displays
all the alarms without providing the entries.
You can also choose to view the alarm information about only the GBTS or the NodeB. In the GBTS
l
List or NodeB List area of the MBTS Auto Deployment window, right-click a record, and then choose
Open Monitor Window from the shortcut menu. The alarm monitoring window of the GBTS or NodeB
is displayed.
Double-click an alarm to be handled, and then click the link provided in Reason in the
displayed dialog box of details.
Rectify the alarm according to the alarm handling suggestions.