24 Operation principle and hardware description
The figure below shows the simplified main circuit diagram of the drive.
ACS560
1
L1
L2
L3
1
L1
L2
L3
1
Rectifier. Converts alternating current and voltage to direct current and voltage.
2
DC link. DC circuit between rectifier and inverter.
3
Inverter. Converts direct current and voltage to alternating current and voltage.
4
Built-in brake chopper (R-, R+/UDC-, UDC+) in frames R0...R2 and (R-, R+/UDC+) in frame R3.
Conducts the surplus energy from the intermediate DC circuit of the drive to the brake resistor when
necessary. The chopper operates when the DC link voltage exceeds a certain maximum limit. The
voltage rise is typically caused by deceleration (braking) of a high inertia motor. The user obtains
and installs the brake resistor when needed.
5
DC connection (UDC+, UDC-), for an external brake chopper in frames R4...R8.