Managing Alarms - Siemens RX1500 User Manual

Ruggedcom rox ii series
Hide thumbs Also See for RX1500:
Table of Contents

Advertisement

Chapter 4
System Administration
Navigate to admin. The Session Limits form appears.
2.
Figure 201: Session Limits Form
1. Maximum Sessions Total Box
3.
Configure the following parameter(s) as required:
Parameter
Maximum Sessions Total
4.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
5.
Click Exit Transaction or continue making changes.
Section 4.6

Managing Alarms

The alarm system in ROX II notifies users when events of interest occur. The system is highly configurable,
allowing users to:
• Enable/disable most alarms, with the exception of mandatory alarms
• Configure whether or not an alarm triggers the failsafe relay and illuminates the alarm indicator LED on the
device
• Configure the severity of most alarms (i.e. emergency, alert, critical, error, etc.), with the exception of some
where the severity is fixed
Each alarm is categorized by its type (or subsystem):
Alarm Type
Admin
Chassis
Switch
Eth
WAN
Cellmodem
190
1
Description
Synopsis: unbounded
Default: 70
Puts a limit on the total number of concurrent sessions to ROX.
Description
Admin alarms are for administrative aspects of the device, such as feature-key problems.
Chassis alarms are for physical or electrical problems, or similar events of interest. This includes irregular
voltages at the power supply or the insertion or removal of a module.
Switch alarms are for link up/down events on switch interfaces.
Eth alarms are for fe-cm port related events, such as link up/down events.
WAN alarms are for T1/E1 and DDS interface related events, such as link up/down events.
Cellular alarms are for cellular interface related events, such as link up/down events.
RUGGEDCOM ROX II
User Guide
Managing Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rx1501Rx1510Rx1511Rx1512

Table of Contents