Chapter 3
Device Management
Figure 37: NETCONF Summary Log Form
1. Enabled Check Box
3.
Configure the following parameter(s) as required:
Parameter
Enabled
4.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
5.
Click Exit Transaction or continue making changes.
Section 3.9.3.4
Enabling/Disabling the NETCONF Trace Log
The NETCONF trace log details all NETCONF protocol transactions, including successful and failed transactions.
CAUTION!
Configuration hazard – risk of reduced performance. Enabling diagnostic logging will significantly affect
the performance of ROX II. Only enable diagnostic logging when directed by Siemens.
To enable or disable the NETCONF Trace log, do the following:
1.
Change the mode to Edit Private or Edit Exclusive.
2.
Navigate to admin » logging » diagnostics. The NETCONF Trace Log form appears.
Figure 38: NETCONF Trace Log Form
1. Enabled Check Box
3.
Configure the following parameter(s) as required:
48
Description
Default: false
Enables/Disables NETCONF logging to the netconf.log.
Enabling/Disabling the NETCONF Trace Log
RUGGEDCOM ROX II