2.5.3 Connecting power supply to PMC large
Location
The controller is shown lying down in order to show the cables. Please note that
the PMC large must be mounted in an upright position.
xx1100000506
A
B
C
D
E
F
G
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: J
G
Incoming power (3 phase)
Line filter
Transformer
(can be left out for 3-phase if using incoming 3-phase of 400-480V)
(can be left out for 2-phase if using incoming single phase of 230V)
Inductor
Power supply 3 x 400-480V
Power supply 230V (2 phase)
Power supply 230V from the Drive Module to the Control Module
© Copyright 2007-2018 ABB. All rights reserved.
2 Installation and commissioning
2.5.3 Connecting power supply to PMC large
E
D
F
Continues on next page
A
B
C
61