Call Progress Tone Detector Setup - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

Issue 0.1
Program 80 : Basic Hardware Setup for System
Level
IN
Description
Use Program 80-04 : Call Progress Tone Detector Setup to define the various levels and timers for
the Call Progress Tone Detector.
Tone Detector Type:
• 1 = Dial Tone for Trunk
• 2 = Busy Tone for Trunk
• 3 = Ring Back Tone for Trunk
• 4, 5 = Reserved
Input Data
Tone Detector Type Number
I
e t
m
N
o
01
Detection Level
02
Min. Detection Level
03
S/N Ratio
04
No Tone Time
05
Pulse Count
06
ON Minimum Time
07
ON Maximum Time
08
OFF Minimum Time
09
OFF Maximum Time
12
Frequency No. 1
13
Frequency No. 2
14
Twist Level
Programming Manual

80-04 : Call Progress Tone Detector Setup

1 = DialToneforTrunk
2 = Busy Tone for Trunk
3 = Ring Back Tone for Trunk
4 = --- Reserved ---
5 = --- Reserved ---
I
e t
m
Input Data
0 = 0 dBm ~ - 25 dBm
1 = - 5 dBm ~ - 30 dBm
2 = - 10 dBm ~ - 35 dBm
3 = - 15 dBm ~ - 40 dBm
4 = - 20 dBm ~ - 45 dBm
5 = - 25 dBm ~ - 50 dBm
6 = - 30 dBm ~ - 55 dBm
0~15
0 = - 10 dBm (0) to - 25 dBm (15)
1 = - 15 dBm (0) to - 30 dBm (15)
2 = - 20 dBm (0) to - 35 dBm (15)
3 = - 25 dBm (0) to - 40 dBm (15)
4 = - 30 dBm (0) to - 45 dBm (15)
5 = - 35 dBm (0) to - 50 dBm (15)
6 = - 40 dBm (0) to - 55 dBm (15)
0~4 (0 dB ~ - 20 dB)
0~255 (30 + 30~7680 ms) (0 = not detect)
1~255 = 60~7680 ms
The formula is 30 + 30N
When set to N = 1, it means 30 + 30
When set to N = 255, it means 30 + 30
7680.
1~255
1~255 (30 + 30~7680 ms)
0~255 (30 + 30~7680 ms)
1~255 (30 + 30~7680 ms)
0~255 (30 + 30~7680 ms)
1~8
(Frequency Table No. set by 80-07)
0~8 (0 = Not Used)
(Frequency Table No. set by 80-07)
0~10 (1 dB ~10 dB)
(0 = Not Used)
SL1000
Program
80
*
1 = 60.
*
255 =
2-407

Hide quick links: