System Alarm Report - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

Issue 0.1
Level
IN
Description
Use Program 90-11 : System Alarm Report to define the details of the system alarm report.
Input Data
Item No.
02
Report Method
When alarm reports are e-mailed, set this option to 1.
E-mail address set in 90-11-08.
04
--- Not Used ---
06
SMTP Host Name
When alarm reports are e-mailed, set the SMTP
name (ex: smtp.yourisp.com). Contact your ISP
(internet service provider) for the correct entry if
needed.
07
SMTP Host Port Number
When alarm reports are e-mailed, set the SMTP host
port number. Contact your ISP (internet service
provider) for the correct entry if needed.
08
To E-mail Address
When alarm reports are e-mailed, set this e-mail
address to which the report should be sent.
09
Reply Address
When alarm reports are e-mailed, set the e-mail
address where replies should be e-mailed.
10
From Address
When alarm reports are e-mailed, set this e-mail
address for the station sending the report.
11
DNS Primary Address
When alarm reports are e-mailed, set the DNS
primary address.
12
DNS Secondary Address
When alarm reports are e-mailed, set the DNS
secondary address.
13
Customer Name
When alarm reports are e-mailed, enter a name to
identify the particular system.
Conditions
None
Feature Cross Reference
None
Programming Manual
Program 90 : Maintenance Program
Item

90-11 : System Alarm Report

Input Data
0 = No Report
1 = E-mail Address
Up to 255 Characters
0~65535
Up to 255 Characters
Up to 255 Characters
Up to 255 Characters
0.0.0.0~255.255.255.255
0.0.0.0~255.255.255.255
Up to 255 Characters
SL1000
Program
90
Default
0
No Setting
25
No Setting
No Setting
No Setting
0.0.0.0
0.0.0.0
No Setting
2-505