Issue 0.1
Program 81 : Basic Hardware Setup for Trunk
Level
IN
Description
Use Program 81-11 : Tie Line Initial Setup to define the various initial data for DID/ TLI/DTI
packages.
Input Data
Trunk Port Number
Item
I
e t
No.
01
DP Interdigit Time Selection
The DP Interdigit Time is the minimum
pause time between dial pulses. Select
either Pattern A or pattern B.
02
Prepause Time Selection
Specify the loop open time for a hookflash
signal sent to the Tie Line when the Recall
key on a multiline terminal is pressed. A
Single Line Telephone (SLT) generates a
hookflash to the Tie Line when a SLT hook-
flash is assigned.
03
Tie Line Answer Detect Time Selection
Specify the time before the system answer
(Off-Hook) is recognized as an answer.
04
Tie Line Release Detect Time Selection
Specify the circuit disconnect detected on
the Tie Line on the distant system side is
recognized as Tie Line.
05
Incoming Signal Detect Time Selection
Specify the time after the incoming signal
from another system is detected before the
acknowledge signal is sent out.
06
Loop Off-Guard Time Selection
Assign loop off-guard time to prevent noise
that could cause the system to be unable
to answer an incoming Tie line.
07
Length of Wink Signal Selection
Specify the time a wink pulse is sent to
another system.
08
Length of Delay Signal Selection
Specify the time a delay pulse is sent to
another system.
09
Incoming Interdigit Timeout Selection
Specify the time that an address signal is
missing during the incoming call detection
process before an error tone is returned to
the other system.
Programming Manual
m
0 = Pattern A
(Pattern A: 10pps - 650ms,
20pps - 500ms)
1 = Pattern B
(Pattern B: 10pps - 800ms,
20pps - 800ms)
1~4
(1~4 = 0.5~2.0 seconds)
(5~15 = 3.0~13 seconds)
(0 = No Setting)
1~15
(130ms~1950ms)
(0 = No Setting)
1~15
(130ms~1950ms)
(0 = No Setting)
Wink Start
1~15
(130ms~1950ms)
(0 = No Setting)
Delay
1~15
(30ms~450ms)
(0 = No Setting)
1~4
(0.5sec~2.0sec)
5~15
(3sec~13sec)
(0 = No Setting)
0~15
(30ms~480ms)
1~15
(300ms~4.5sec)
(0 = No Setting)
0 = ∞ (Nolimit)
1~15
(1~15 sec)

81-11 : Tie Line Initial Setup

1~126
n I
p
t u
D
a
a t
SL1000
D
e
a f
u
t l
1
(Pattern B)
0
(No Setting)
4
(520ms)
4
(520ms)
Wink Start
3
(390 ms)
Delay
3
(90 ms)
4
(2.0 sec)
5
(180 ms)
1
(300 ms)
6 (6 sec)