Issue 0.1
Item No.
Item
10
TDM Tx Level Control
11
TDM Tx LevelControl Level
12
TDM Tx AutomaticLevelControl
Level
13
TDM Tx HLC Threshold
14
TDM Tx Gain Compression mode 0 = Disable
15
TDM Tx Gain Compression
Threshold
16
TDM Rx Level Control
17
TDM Rx LevelControl Level
18
TDM Rx AutomaticLevelControl
Level
19
RTP Echo Canceller mode
20
RTP Echo Canceller NLP mode
21
RTP Echo Canceller Comfort-
Noise mode
22
RTP Echo Canceller NLP
Threshold
23
RTP Echo Canceller Tail
Displacement
Programming Manual
Input Data
0 = Disable
1 = TxLevelControl mode
2 = TxAutomaticLevelControl mode
3 = HLC
0-16 (-24 ~ 24dB)
0 = -24 dB
1 = -21 dB
2 = -18 dB
:
8 = 0 dB
:
14 = 18 dB
15 = 21 dB
16 = 24 dB
0-12 (-42 ~ -6 dBm)
0 = -42 dBm
1 = -39 dBm
:
7 = -21 dBm
:
11 = -9 dBm
12 = -6 dBm
0-42 (-42 ~ 0dB m)
0 = -42 dBm
1 = -41 dBm
:
42 = 0 dBm
1 = Enable
0 = -42 dBm
1 = -41 dBm
:
42 = 0 dBm
0 = Disable
1 = Rx Level Control mode
2 = Rx Automatic Level Control
Flag
0-16 (-24 ~ 24 dB)
0 = -24 dB
1 = -21 dB
2 = -18 dB
:
8 = 0 dB
:
14 = 18 dB
15 = 21 dB
16 = 24 dB
0-12 (-42 ~ -6 dBm)
0 = -42 dBm
1 = -39 dBm
:
7 = -21 dBm
:
11 = -9 dBm
12 = -6 dBm
0 = Disable
1 = Enable
0 = Disable
1 = Enable
0 = Disable
1 = Enable
0-15
0-89 (0 ms ~ 890 ms)
SL1000
Default
3
8
Program
84
7
41
1
41
0
8
7
0
0
1
12
0
2-485